Technical Data Sheet
Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification; lot-specific certificates ship with every order.
| Grade | Concentration | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade — | — | — | current | current |
| — | 50% | — | SHOPIFY-7858635440170 | View TDS → |
| — | 40% | — | SHOPIFY-7858635407402 | View TDS → |
| — | 34.98% | — | SHOPIFY-7858635374634 | View TDS → |
| — | 29.98% | — | SHOPIFY-7858601656362 | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | Value | Source |
|---|---|---|
| Appearance | Clear to pinkish liquid (dyed) | Published reference |
| Odor | Mild, characteristic | Published reference |
| pH | 9-10.5 | Published reference |
| Specific Gravity (20 °C) | 1.026 (20 °C) | Published reference |
| Density | 1.026 g/mL at 20 °C | Published reference |
| Boiling Point | ~102 °C | Published reference |
| Melting Point | -8 °C (freeze / crystallization onset) | Published reference |
| Flash Point | Not flammable (aqueous solution) | Published reference |
| Solubility (water) | Miscible with water | Published reference |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Inhibited Ethylene Glycol 20/80 with OAT-908 — Data Center Coolant. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Inhibited Ethylene Glycol 20/80 with OAT-908 — Data Center Coolant is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.
Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.1 | 2026-08-17 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.