Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Inhibited Propylene Glycol 35/65 with OAT Inhibitor — Data Center Coolant

35%

CAS Number
57-55-6
Alliance Code
SHOPIFY-7990713942058
Generated
2026-09-09
Revision
1.1
Reviewed
2026-08-17
2D chemical structure of Inhibited Propylene Glycol 35/65 with OAT Inhibitor — Data Center Coolant
Structure · PubChem
Last reviewed 2026-08-17.

Identity & Composition

Product Name
Inhibited Propylene Glycol 35/65 with OAT Inhibitor — Data Center Coolant
Alliance Code
SHOPIFY-7990713942058
Grade
Concentration
35%
CAS Number
57-55-6Adjudicated
Formula
C3H8O2Adjudicated
Molecular Weight
76.09Adjudicated
Product Type
mixture

Specifications

TestSpecificationTypicalMethodSource
Assay34.0 - 36.0 %, by volume35.0 %Interpreted
Propylene glycol concentration34.0 - 36.0 % v/v35.0 %Interpreted
Reserve alkalinity≥ 2.1 mL at 35 vol % propylene glycol2.5ASTM D1121Interpreted
Silicate, phosphate, nitrite, nitrate, borate and amine contentNone detected (< 10 ppm each)0.3 ppmICP-OES / ion chromatographyInterpreted
Foaming tendencyVolume ≤ 150 mL; break time ≤ 5 sPasses testASTM D1881Interpreted
Dipropylene glycol (DPG)0.17 wt% max0.088 wt%GC area % (ASTM E202)Interpreted
Burst protection-46 °F (-43.3 °C) at 35 vol % propylene glycolPasses testDynalene PG series data tableInterpreted
Acidity as Acetic Acid0.0018 % max0.00053 %Interpreted
Chlorides as Cl0.61 ppm max0.14 ppmInterpreted
Heavy Metals as Pb1.8 ppm max0.071 ppmInterpreted
Iron0.36 ppm max0.035 ppmInterpreted
ash0.0018% max0.00028 %Interpreted
Suspended MatterPassPasses testInterpreted
Composition35 % propylene glycol / 65 % deionized water, by volumeConformsBy formulation; confirmed by specific gravityInterpreted

Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade 35%currentcurrent
50%SHOPIFY-7859432226858View TDS →
40%SHOPIFY-7859432194090View TDS →
30%SHOPIFY-7859429277738View TDS →
25%SHOPIFY-7990713909290View TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearancePassInterpreted
Color10 APHA (maximum)Interpreted
OdorMild, characteristicPublished reference
pH9-10.5Published reference
Specific Gravity (20 °C)1.029 (20 °C)Published reference
Density1.029 g/mL at 20 °CPublished reference
Boiling Point~103 °CPublished reference
Melting Point-16 °C (freeze / crystallization onset)Published reference
Flash PointNot flammable (aqueous solution)Published reference
Solubility (water)Miscible with waterPublished reference

Regulatory & Transport

DOT / 49 CFR

UN Number
Not regulatedAdjudicated
Hazard Class
Not regulatedAdjudicated
Packing Group
Not regulatedAdjudicated
Proper Shipping Name
Not regulatedAdjudicated

GHS / OSHA HazCom 2012

Signal Word
Not regulatedAdjudicated
H-Codes (Hazard Statements)
no canonical
P-Codes (Precautionary Statements)
no canonical

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
no canonical
ACGIH TLV
no canonical
NIOSH REL
no canonical
NIOSH IDLH
no canonical

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Inhibited Propylene Glycol 35/65 with OAT Inhibitor — Data Center Coolant. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Application Guidance

Inhibited Propylene Glycol 35/65 with OAT Inhibitor — Data Center Coolant is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.

  • Closed-loop heat transfer and process cooling
  • Data-centre and chilled-water freeze protection
  • HVAC hydronic loops and glycol makeup
  • Freeze and burst protection for idle or seasonal systems
  • Humectant and carrier applications (USP/food-grade propylene glycol only)

Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.

Storage & Handling

Recommended Storage
Cool, dry, well-ventilated area in tightly sealed original containers. Neat glycols are combustible liquids with high flash points (roughly 99–111 °C) and do not require a solvent store; aqueous blends will not sustain combustion. Protect inhibited coolants from contamination and from freezing below their stated protection point.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Chemical-resistant gloves and splash goggles. Ethylene glycol grades are toxic by ingestion and must be kept away from food, drink and animals; propylene glycol grades are not. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizers, strong acids and strong bases. Galvanized (zinc) surfaces are attacked by many inhibited coolant packages. Verify elastomer and gasket compatibility for the service temperature; EPDM is standard for glycol/water service.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
55

Revision History

VersionDateChangeTrigger
1.12026-08-17Canonical data updated: 11 fields changed via the provenance/adjudication pipeline.
  • physicalProperties· canonical change (coa.data_provenance / adjudication)
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • casNumber· canonical change (coa.data_provenance / adjudication)
  • formula· canonical change (coa.data_provenance / adjudication)
  • molecularWeight· canonical change (coa.data_provenance / adjudication)
canonical_change

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.

Inhibited Propylene Glycol 35/65 with OAT Inhibitor — Data Center Coolant — Technical Data Sheet | Alliance Chemical